Attaching the inverter to the mounting bracket
Attaching the in-
verter to the
mounting brack-
et
WARNING!
Danger from inadequate ground conductor connection.
This can result in serious injury and damage to property.
▶
The housing screws provide a suitable ground conductor connection for
grounding the housing and must NOT be replaced by any other screws that
do not provide a reliable ground conductor connection.
The side sections of the housing lid are designed to function as holding and car-
rying handles.
Note! For safety reasons, the inverter is fitted with a latch that prevents the in-
verter from being swung into the mounting bracket unless the DC main switch is
switched off.
-
Never attach the inverter to the mounting bracket or swing it in unless the
DC main switch is switched off.
-
Never use force to attach the inverter or swing it in.
The fastening screws in the data communication area of the inverter are used for
securing the inverter to the mounting bracket. Correctly tightened fastening
screws are a prerequisite if proper contact is to be established between the in-
verter and mounting bracket.
CAUTION!
Danger due to incorrectly tightened fastening screws.
This may result in arcs occurring when the inverter is in operation, which may
lead to fire.
▶
Always use the specified torque when tightening the fastening screws.
1 2
32