IMPORTANT! The PE ground conductor of the AC cable must be laid in such a
way that it is the last to be disconnected in the event that the strain-relief device
should fail.
This can be ensured, for example, by making it somewhat longer and by laying it
in a loop.
If AC cables are laid over the shaft of the DC main switch or across the connec-
tion block of the DC main switch, they may be damaged when the inverter is
swung in, or they may even prevent the inverter from being swung in.
IMPORTANT! Do not lay AC cables over the shaft of the DC main switch or
across the connection block of the DC main switch.
If overlength AC or DC cables are to
be laid in loops in the connection area,
attach the cables with cable ties to the
eyelets provided on the top and bot-
tom of the connection block.