Troubleshooting
Errors in program
sequence
Parting agent does not spray
Parting agent container is full
Cause: Not enough spray
Remedy: Adjust spray amount (spray time or parting agent adjuster)
Cause: Parting agent hose suction filter in the parting agent container is soiled
Remedy: Clean the parting agent hose suction filter with compressed air (see "Starting
up the parting agent nebuliser")
Cause: No signal from robot
Remedy: Check robot program
Cause: Parting-agent injection nozzle blocked
Remedy: Clean parting-agent injection nozzle
Contact After-Sales Service (arrange for parting-agent injection nozzle to be
replaced)
Cause: Vacuum pump faulty
Remedy: Contact After-Sales Service (arrange for vacuum pump to be replaced)
Cause: Mechanical fault on solenoid valve
Remedy: Contact After-Sales Service (arrange for solenoid valve to be replaced)
Welding torch is poorly cleaned or damaged
Cause: Lifting device not adjusted properly
Remedy: Adjust the lifting device
Cause: Cleaning cutter not suited to welding torch shape
Remedy: Fit the correct cleaning cutter
Cause: Cleaning cutter is worn
Remedy: Replace cleaning cutter
Cleaning cutter collides with a contact tip or gas nozzle
Cause: Lifting device not adjusted properly
Remedy: Adjust the lifting device
Cause: Cleaning cutter not suited to welding torch shape
Remedy: Fit the correct cleaning cutter
Cause: Cleaning cutter is worn
Remedy: Replace cleaning cutter
Cause: Incorrect swivel mechanism stop angle
Remedy: Adjust the swivel mechanism stop angle