6
Press the Info button several times in a row to display the parameters in the following
sequence:
Retrieving para-
meters during
charging
Example: current battery
voltage
Interrupting
charging
1. Press Start/Stop button to interrupt charging.
- Displays the current charging status
2. By pressing the Info button, the following para-
meters can be retrieved:
- Charged ampere hours
3. Press Start/Stop button again to resume char-
ging
- Current battery voltage
- Selected characteristic
- Current battery temperature (only with
temperature-controlled charging option)
Finishing char-
ging/disconnec-
ting the battery
1. Finish charging
2. Disconnect (-) charger lead from battery
3. Disconnect (+) charger lead from battery
CAUTION! Risk of explosion from sparks when disconnecting charger leads.
Before disconnecting the charger leads, press the Start/Stop button to stop
charging.
4.
Example: current battery
temp. (only with tempe-
rature-controlled
charging option)
Example: charged