98
no | IGn
Cause: "Ignition time out" function is active; no current started flowing before the
length of wire specified in the set-up menu had been fed. The power source
safety cut-out has tripped.
Remedy: Shorten the wire end; press the torch trigger again; clean the surface of the
workpiece; if necessary, increase the wire length until the safety cut-out trips
in "Set-up menu: Level 2".
EPG | 29
Cause: The required wire-feed unit is not available for the selected characteristic
Remedy: Check plug connections for the hosepack
EPG | 35
Cause: RL calibration failed.
Remedy: Check grounding (earthing) cable, current cable or hosepack and replace if
necessary, restart RL calibration
no | GAS
Cause: The Gas watchdog option has detected that there is no gas pressure
Remedy: Connect a new gas cylinder or open the gas cylinder valve/pressure regulator,
restart "Gas watchdog" option, reset "no | GAS" error message by pressing
any button.