Connecting the mains cable
General A strain-relief device for the following cable cross-sections is fitted to the power source:
*) Canada/US cable type: extra-hard usage
Strain-relief devices for other cable cross-sections must be designed accordingly.
Stipulated mains 
cables and strain-
relief devices
*) Canada/US cable type: extra-hard usage
The item numbers of the different cables can be found in the spare parts list towards the 
end of the document.
American wire gauge
Connecting the 
mains cable
If no mains cable is connected, a mains cable that is suitable for the connection voltage 
must be fitted before commissioning.
The PE conductor should be approx. 10 - 15 mm (0.4 - 0.6 in.) longer than the phase con-
ductors.
An illustration of the mains cable connection can be found in the following sections: "Fitting 
the strain-relief device" or "Fitting the strain-relief device for Canada / US". To connect the 
mains cable, proceed as follows:
Remove the side panel from the device
Push the mains cable in far enough to make it possible to connect the PE conductor 
and the phase conductors to the block terminal properly.
Fit ferrules to the PE conductor and phase conductors
Connect the PE conductor and phase conductors to the block terminal
Use the strain-relief device to secure the mains cable 
Fir the side panel of the device
Power source Cable cross-section
Canada/US Europe
TSt 3500c AWG 12 *) 4G2.5
Power source Mains voltage Cable cross-sec-
tion
Canada/US
Europe
TSt 3500c 3 x 380 / 400 V AWG 12 *) 4G2.5
3 x 460 V AWG 12 *) 4G2.5
CAUTION! If no ferrules are used, there is a risk of injury and damage from short 
circuits between the phase conductors or between the phase conductors and the 
PE conductor. Fit ferrules to all phase conductors and the PE conductor of the 
stripped mains cable.