59
EN
Special 4-step
mode:
variant 4
Variant 4 of the special 4-step mode is activated when the SFS set-up parameter is set to
"4".
- Welding start-up and welding: briefly pull back and release the torch trigger - the weld-
ing current will rise at the specified upslope value from the starting current I
S
until it
reaches the main current value I
1
.
- Push forward and hold the torch trigger for intermediate lowering
- Release the torch trigger to resume the main current I
1
- End of welding: briefly pull back and release the torch trigger
Special 4-step mode: variant 4
I
t
I
1
GPr
I
S
t
down
I
E
G-L
G-H
I
1
I
2
t
up
t
E
t
S