90
tP3 | xxx
Note: xxx stands for a temperature value
Cause: Overtemperature in the primary circuit of the power source
Remedy: Allow power source to cool down
tP4 | xxx
Note: xxx stands for a temperature value
Cause: Overtemperature in the primary circuit of the power source
Remedy: Allow power source to cool down
tP5 | xxx
Note: xxx stands for a temperature value
Cause: Overtemperature in the primary circuit of the power source
Remedy: Allow power source to cool down
tP6 | xxx
Note: xxx stands for a temperature value
Cause: Overtemperature in the primary circuit of the power source
Remedy: Allow power source to cool down
tS1 | xxx
Note: xxx stands for a temperature value
Cause: Overtemperature in the secondary circuit of the power source
Remedy: Allow power source to cool down
tS2 | xxx
Note: xxx stands for a temperature value
Cause: Overtemperature in the secondary circuit of the power source
Remedy: Allow power source to cool down
tS3 | xxx
Note: xxx stands for a temperature value
Cause: Overtemperature in the secondary circuit of the power source
Remedy: Allow power source to cool down
tSt | xxx
Note: xxx stands for a temperature value
Cause: Overtemperature in the power source control circuit
Remedy: Allow power source to cool down
Err | 051
Cause: Mains undervoltage: The mains voltage has dropped below the lower limit of
the tolerance range (see section "Technical data")
Remedy: Check the mains voltage

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius TransTig 2500 and is the answer not in the manual?

Fronius TransTig 2500 Specifications

General IconGeneral
BrandFronius
ModelTransTig 2500
CategoryWelding System
LanguageEnglish

Related product manuals