Rec. Status Tally
This function is designed for use with cameras that output Start/Stop Record ags in the ancillary data of their serial digital
output. To activate this function set Rec. Status Tally to a function button and press that function button once. While active
the monitor’s red tally light will turn on when the Start Record SDI ag is detected and will turn the red tally light off when the
Stop Record SDI ag is detected.
PAP - Live Side by Side and Picture In Picture Viewing
Corresponding controls can be found in the Video Menu to change your PAP Secondary Input and PAP Mode, allowing
you to select Picture In Picture, Picture And Picture (Side-By-Side Monitoring), Picture On Picture, Vertical Split Screen, or
Horizontal Split Screen. You can use the Variable Wipe function in conjunction with the Vertical and Horizontal Split modes
to set a custom split position other than the default of center screen.
As of rmware version 1.1.03-2144 you can page through the different PAP viewing modes using the up and down
arrow keys while the function is active.
Dual Link
3Gbps SDI is the preferred connectivity method if available, but if single link 3Gbps SDI output from your source is not
available you can use the Dual Link function to activate Dual Link SDI support. To activate this capability rst select SDI 1 as
your input. Then set Dual Link to a function button. Then press that designated function button to turn on Dual Link mode.
Once active you may need to set your SDI format manually if no payload ID is present in the signal. To do this go to the SDI
format section of the Video Menu and select the appropriate format.
DIT LUT
Use to active DIT (Look) LUTs stored on the monitor. Scroll between LUT positions using the monitor’s up and down keys.
See Appendix A for details on saving DIT (Look) LUTs to the monitor.
Overscan
The Overscan function can work with 1:1 Pixel mapping mode on or off. With 1:1 Pixel to Pixel mapping mode turned off
the Overscanned image is scaled full screen. With 1:1 Pixel to Pixel mapping mode turned on the image remains unscaled,
but the area lying outside of the active scan area is blacked out. This area represents the same area not visible with Pixel
to Pixel mode off (continued next page).
Black Detail Mode
A diagnostic tool that clips the top 25% of code values and then uses the monitor’s full native range to display the remaining
75% of code values. This has the net effect of stretching separation of levels, especially in lowlights, making low-level detail
easier to discern. Black Detail Mode should NOT be used for normal monitoring applications, it is strictly a QC / analysis tool
for examining low code level details more easily.