© 2023 Flanders Scientic, Inc.
24
Return to Table of Contents
Scopes & Audio Meters Menu
Main Menu Scopes & Audio Meters
Function Scopes & Audio Meters Prole 1
Real Time Scopes Window 1 Luminance
Scopes & Audio Meters Window 2 Vector
Video Waveform Position Bottom Right
Audio Scopes Stack Horizontal
Marker Waveform Scale IRE Level
Alarm Audio Display Mode Pairs
OSD Alignment Level -18 dBFS
GPI Permitted Max Level -9 dBFS
Color Management Audio Display Channels 1-16
System Ballistics True Peak
System Status Peak Hold Time 2
Support
Scopes & Audio Meters Prole 1, 2, 3
In addition to Real Time Scopes a wide variety of additional scopes and meters are available. These scopes and meters
update approximately every 2 to 3 frames and work in both Normal and Noise Reduction processing modes on DM series
monitors. The Scopes & Audio Meters menu allows you to setup three Scopes & Audio Meters Proles, each capable of
storing all of the congurable settings found on the Scopes & Audio Meters Menu. To congure a Prole simply select the
Prole number, 1 through 3, from the top of the Scopes & Audio Meters menu page. Once you have selected the desired
prole number any settings you change will become associated with that prole number. Changing from one prole to
another from the Scopes and Audio Meters menu will automatically recall your last settings for that prole. Once you have
congured your Scopes & Audio Meters proles you can assign a specic function key to a particular prole, which allows
you to instantly switch between different types of Scope and/or Audio Meters modes without having to go back into the on-
screen menu.
Window 1 & Window 2
Two scope windows can be displayed simultaneously so you can view any two of the following modes at the same time:
Luminance (Standard Waveform), Vector Scope, Hue Vector*, RGB Parade, GBR Parade, RGB Overlay, YCbCr, YCbCr
Overlay, Column (YRGB Peak), Histogram, Color Histogram, RGB Histogram, Audio Loudness, Audio Phase, and Vertical
Audio Level Meter. Please note that displaying two Scope Windows at the same time will cause the Scopes to update more
slowly than displaying just one Scope Window. To display just one scope Window select OFF in the secondary window
selection. An additional audio level meter mode called horizontal audio level meter is also selectable. This mode displays
meters horizontally across the top of the screen, but cannot be used in conjunction with any other Scope modes. Waveform
Intensity and Gain can be adjusted by turning the H POS and V POS rotary knobs. Default Scope Intensity as
of rmware version 9.42 is 75% of the maximum level. Hue Vector Intensity, Gain, Reference Vector Angle, and
Percentage of Reference Vector can be adjusted with the H POS, V POS, Ref POS, and F Stop rotary knobs. Audio
Loudness metering can be paused and reset using the H POS rotary knob.
*Hue Vectors graticule designed by Alexis Van Hurkman and used under Creative Commons License.
Waveform Position
Use the Waveform Position toggle to select in what area of the screen you would like your Scopes to be displayed.
Scopes Stack
Use this option to select whether the Scope Windows are stacked vertically or positioned horizontally next to each other
when utilizing two Scope Windows.
NOTE: The Scope & Audio
Meters Menu only sets your
Waveform, Vector, & Audio Level
Meter display preferences. To
toggle the on-screen display
of your congured Scopes &
VU Meters proles assign the
Scopes & VU Meters proles to
specic keys. See the Function
Menu section of this manual for
more details.