• Selecting the device in the Project panel and navigating to Device…Manage Device
Parameters...
A parameter is accessible and actively scanned (read from and written to the inverter) only if its
corresponding checkbox is enabled. Likewise, a parameter is inaccessible if its checkbox is disabled.
Parameters that are accessed more frequently or require a faster update rate should be set to high
priority. All other parameters should be set to low priority.
The parameter list serves as a us eful reference when configuring objects.
Figure 13: Manage Device Parameters
5.7 Backup and Restore Parameters
The parameter values can be backed up from the inverter and restored to the inverter (refer to Figure 14
and Figure 15). This allows for easy inverter cloning. The backup parameter values are stored as a CSV
file. A parameter value can be excluded from the list by disabling the corresponding checkbox. The
parameter value can also be modified before the backup and restore is executed. Note that backup and
restore does not modify the parameter list (refer to section 5.6). The backup and restore parameter
configurations are found by:
• Right-clicking on the device in the Project panel and choosing Backup Parameters… or Restore
Parameters… from the context-sensitive menu.
• Selecting the device in the Project panel and navigating to Device…Backup Parameters from
Device... or Restore Parameters to Device…