OPC-PRT
Multiprotocol Ethernet Interface
Thank you for purchasing the OPC-PRT Multiprotocol Ethernet Interface.
This product is designed to connect the FRENIC-Ace series of inverters to Ethernet
communication networks. Please read this instruction manual thoroughly in order to become
familiar with the proper interface handling, installation and usage procedures.
Improper handling may inhibit correct operation or caus e premature interface failure.
Please deliver this instruction manual to the end user of the interface, and retain it in an
accessible location.
For inverter usage instructions, please refer to the applicable inverter instruction manual.
Instruction Manual

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Fuji Electric OPC-PRT and is the answer not in the manual?

Fuji Electric OPC-PRT Specifications

General IconGeneral
BrandFuji Electric
ModelOPC-PRT
CategoryRecording Equipment
LanguageEnglish

Summary

INSTALLATION

Pre-Installation Instructions

Covers essential safety warnings and preparation steps before installing the interface card.

Installation Procedure

Provides step-by-step guidance on physically mounting and connecting the interface card to the inverter.

INVERTER FUNCTION CODE SETTINGS

Inverter Control-Related Settings

Explains function codes for network control, command words, and frequency references.

Inverter Reaction to Network Timeout Conditions

Defines how the inverter responds to communication loss or timeout events.

FUNCTION CODE NUMBERING AND BEHAVIOR

Register Numbers

Details the mathematical conversion formula for mapping function codes to Modbus register numbers.

FUJI CONFIGURATION STUDIO

Ethernet Settings

Configures network parameters like IP address, subnet mask, and default gateway.

Internal Logic Settings

Configures fail-safe actions for network timeout events.

EMBEDDED WEB SERVER

FIRMWARE

Update Procedure

Step-by-step instructions for performing firmware updates via USB or FTP connections.

PROTOCOL-SPECIFIC INFORMATION

9.2 EtherNet/IP

Covers EtherNet/IP protocol specifics, including I/O messaging and examples for ControlLogix PLCs.

9.5 PROFINET IO

Information on PROFINET IO protocol and examples for configuring with TIA Portal and Proficy.

TROUBLESHOOTING