1-8. COMPRESSOR CONTROL
1. OPERATION SPEED RANGE
The operation speed of the compressor is different based on the operation mode as
shown in Table 8.
Cooling Heating
Min Max Min Max
Dry
(Table 8 : Compressor Operation Speed Range)
2. OPERATION SPEED CONTROL AT START UP
The compressor speed soon after the start-up is controlled as shown in Figure 8.
(Fig.8 : Compressor Control at Start-up)
01-11
AO*A30LFTL
AO*A36LFTL
AOTA30LGTL
16rps 72rps 16rps 90rps 29rps
60 (sec)120 180
30
47
60
(rps)