02-04
Compressor temperature error
Operation LED Blinking Pattern
Normal operation OFF
5sec ON / 1sec OFF
0.5sec ON / 0.5sec OFF
2sec ON / 2sec OFF
0.1sec ON / 2sec OFF
0.1sec ON / 0.1sec OFF
5sec ON / 5sec OFF
2sec ON / 5sec OFF
5sec ON / 01sec OFF
Continuously lighting
Protected operation
0.5sec 0.5sec 2sec
ON
OFF
1. ERROR DISPLAY
Outdoor LED Blink (1 to 16 times) 0.5sec ON / 0.5sec OFF blinking
2-1-3 OUTDOOR UNIT DISPLAY
Discharge temperature error
Outdoor unit fan motor error
19
Error contents LED Flashing Pattern
Trouble
shooting
Outdoor unit sensor error
(Discharge or Outdoor or Heat EX)
IPM error
Compressor rotor location cannot detect
15
9
5, 7, 8
22
16
CT error
17
18
2. ERROR DISPLAY METHOD
3. NORMAL OPERATION DISPLAY
Active filter module error