6. SYSTEM DESIGN
8) Auto restart
Enable or disable automatic restart after a power interruption.
(
... Factory setting)
Setting description Function number Setting value
Enable
40
00
Disable 01
*Auto restart is an emergency function such as for power outage etc.
Do not attempt to use this function in normal operation.
Be sure to operate the unit by remote controller or external device.
9) Room temperature sensor switching
(Only for Wired remote controller)
When using the Wired remote controller temperature sensor, change the setting to "Both" (01).
(
... Factory setting)
Setting description Function number Setting value
Indoor unit
42
00
Both 01
00: Sensor on the indoor unit is active.
01: Sensors on both indoor unit and wired remote controller is active.
*Remote controller sensor must be turned on by using the remote controller.
10) Remote controller custom code
(Only for wireless remote controller)
The indoor unit custom code can be changed.
Select the appropriate custom code.
(
... Factory setting)
Setting description Function number Setting value
A
44
00
B 01
C 02
D 03
11) External input control
"Operation/Stop" mode or "Forced stop" mode can be selected.
(
... Factory setting)
Setting description Function number Setting value
Operation/Stop mode
46
00
(Setting prohibited) 01
Forced stop mode 02
12) Room temperature sensor switching (Aux.)
To use the temperature sensor on the wired remote controller only, change the setting to
"Wired remote controller" (01). This function will only work if the function setting 42 is set at
"Both" (01)
(
... Factory setting)
Setting description Function number Setting value
Both
48
00
Wired remote controller 01
- (06 - 86) -
SYSTEM
DESIGN
SYSTEM
DESIGN

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ASHG12LMCA and is the answer not in the manual?

Fujitsu ASHG12LMCA Specifications

General IconGeneral
TypeSplit system
TimerYes
Multi-split-
Product colorWhite
Dehumidifying capacity1.8 l/h
Timer duration (maximum)24 h
Air conditioner functionsCooling, Dehumidifying, Heating
Cooling capacity in watts (max)3900 W
Cooling capacity in watts (min)900 W
Heating capacity in watts (max)5300 W
Cooling capacity in watts (nominal)3400 W
Cooling energy efficiency (EER, W/W)3.5
Heating energy efficiency (COP, W/W)3.92
Seasonal efficiency rating (cooling) (SEER)7
Heating capacity in watts (nominal) (Warmer heating season)- W
Heating capacity in watts (nominal) (Average heating season)4000 W
Seasonal efficiency rating (heating) (SCOP) (Average heating season)4
AC input voltage230 V
AC input frequency50 Hz
Design load (cooling)- kW
Energy efficiency class (cooling)A++
Power consumption (cooling) (max)970 W
Power consumption (heating) (max)1020 W
Annual energy consumption (cooling)170 kWh
Hourly energy consumption (cooling)- kWh
Energy efficiency class (heating) (Average heating season)A+
Annual energy consumption (heating) (Average heating season)1225 kWh
Indoor unit typeWall-mountable
Indoor unit depth203 mm
Indoor unit width840 mm
Indoor unit height268 mm
Indoor unit weight8500 g
Indoor unit noise level (high speed)43 dB
Outdoor unit depth293 mm
Outdoor unit width663 mm
Outdoor unit height535 mm
Outdoor unit weight26000 g
Outdoor unit noise level50 dB
Airflow750 m³/h

Related product manuals