Access Method
This section explains the connection configurations between server Host Bus Adapters (HBAs) and
ETERNUS AF
host interface ports.
■
Single Path Connection
A single path configuration connects the ETERNUS AF to a server via a single path.
The server cannot access an ETERNUS AF when a component (such as a controller, HBA, switch, or cable) on the
path has a problem. The system must be stopped when a failed component on a path needs to be replaced or
when the controller firmware needs to be updated.
In a single path connection configuration, the path failover and load balancing functions are not supported.
A multipath connection configuration is recommended to maintain availability when a problem occurs.