EasyManua.ls Logo

Fujitsu ETERNUS AF250 S2 - Table 22 FTRP Thresholds; Table 23 FTV Thresholds

Fujitsu ETERNUS AF250 S2
171 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FTRP Thresholds
There are two FTRP usage thresholds: Attention and Warning.
Table 22 FTRP Thresholds
Threshold Selectable range Default Setting conditions
Attention 5 (%) to 80 (%) 75 (%)
Attention threshold £ Warning threshold
The "Attention" threshold can be omitted.
Warning 5 (%) to 99 (%) 90 (%)
FTV Thresholds
There is only one FTV usage threshold: Attention. If there is insufficient capacity for the FTV unallocated space
in the pool free space, an alarm notification is sent. The threshold is determined by the ratio of free space in
the FTSP and the unallocated FTV capacity.
Table 23 FTV Thresholds
Threshold Selectable range Default
Attention 1 (%) to 100 (%) 80 (%)
When the Flexible Tier function is enabled,
32 work volumes (physical capacity is 0MB) are created. The
maximum number of volumes that can be created in the ETERNUS AF decreases by the number of work
volumes that are created.
The FTRP capacity that can be used for VVOLs differs from the maximum Thin Provisioning Pool capacity. For
details, refer to "VMware VVOL" (page 115).
1. Function
Operations Optimization (Deduplication/Compression and Storage Virtualization)
55
FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays
Design Guide (Basic)
Copyright 2019 FUJITSU LIMITED