EasyManua.ls Logo

Fujitsu ETERNUS AF250 S2 - READY LED Not On; FAULT LED On

Fujitsu ETERNUS AF250 S2
171 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Improving Host Connectivity
Host Affinity
The host affinity function prevents data from being damaged due to inadvertent storage access. By defining a
server that can access the volume, security can be ensured when multiple servers are connected.
Figure 43 Host Affinity
Permission for Server A
LUN#0
Volume#0 ... LUN#255
Volume#255
Permission for Server B
LUN#0
Volume#256 ... LUN#255
Volume#511
Permission for Server C
LUN#0 Volume#512 ... LUN#255 Volume#767
Permission for Server D
LUN#0 Volume#768 ... LUN#255 Volume#1023
Switch
Server A
LUN#0
:
LUN#255
Server B
LUN#0
LUN#255
Server D
LUN#0
:
LUN#255
Server C
LUN#0
:
LUN#255
Volume#0
:
Volume#255
Volume#256
:
Volume#511
Volume#512
:
Volume#767
Volume#768
Volume#1023
:
Port
Port
:
ETERNUS AF
1. Function
Improving Host Connectivity
76
FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays
Design Guide (Basic)
Copyright 2019 FUJITSU LIMITED
P3AG-1822-09ENZ0

Table of Contents