Appendix A Event Notification Message List
A.1 Message Format
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation-
Copyright 2013 FUJITSU LIMITED P3AM-4842-12ENZ0
104
â– Descriptions of the event notification contents
Number Description
Subject 1 The model name of the ETERNUS DX Disk storage system is displayed.
2 The serial number of the ETERNUS DX Disk storage system is displayed.
3 The Severity of the event is displayed. One of the following items is displayed for the
message:
Error: indicates an error
Warning: indicates a warning
Information: indicates that information is provided
Test: indicates a test mail
Message 4 A comment that is set using the e-mail notification setting of ETERNUS Web GUI or ETERNUS
CLI is displayed.
5 A message that indicates the event is displayed.
For more details, refer to "A.2 Message List" (page 112)
.
6 The message event type and the event code that are separated by a blank are displayed.
One of the following letters is output as an event type:
"P", "J", "M", "I", "R"
Event code is an 8-digit hexadecimal number according to the message.
For more details, refer to "A.2 Message List" (page 112)
.
7 The Severity of the event is displayed. One of the following items is displayed for the
message:
Error: indicates an error
Warning: indicates a warning
Information: indicates that information is provided
Test: indicates a test mail
8 The event serial number, which increases from the startup of the ETERNUS DX Disk storage
system, is displayed in the "
x-yyyy
" format.
x
: Controller number (0 or 1)
yyyy
: Serial number
The event serial number is reset when the ETERNUS DX Disk storage system is turned on or
restarted.
9 The time when the event occurred is displayed in the "
Mmm dd hh:mm:ss yyyy
" format.
Mmm
: Abbreviation of each month (Jan – Dec)
dd
: Date. If the date is a single digit, "0" is output before the date number.
hh
:
mm
:
ss
: "
hh
" indicates the hour (00 – 23), "
mm
" indicates minutes (00 – 59), and "
ss
"
indicates seconds (00 – 59).
yyyy
: The year is display with four digits.
10 The detailed information of the event is displayed. For multiple process results, each process
result is displayed on a separate line.