EasyManua.ls Logo

Fujitsu Eternus DX80 S2 - Figure 1.15 Host Interface (SAS); Figure 1.16 Power Supply Unit

Fujitsu Eternus DX80 S2
186 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 1 Components
1.1 Controller Enclosure
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation-
Copyright 2013 FUJITSU LIMITED P3AM-4842-12ENZ0
21
SAS
Figure 1.15 Host interface (SAS)
Part explanation
- Host interface ports (SAS) (from left to right: Port#0 and Port#1 in CA#0, Port#0 and Port#1 in CA#1)
These are the SFF-8088 connectors to connect miniSAS cables.
System Capacitor Unit (SCU)
A SCU is installed in a controller as a backup power source in case of power outage.
The SCU is charged from an external power source while the ETERNUS DX Disk storage system is running
normally. If a power outage is detected, data in the cache memory is saved to the non-volatile memory in the
controller using the SCU. The saved data is retained in the non-volatile memory indefinitely.
1.1.4.2 Power Supply Units
The power supply unit transforms input AC power from a power socket to DC power and supplies power to each
component.
Each power supply unit contains fans.
Figure 1.16 Power supply unit
SAS
Port#0 Port#1Port#0 Port#1
Installed host interfaces in the controller
Host interface (CA#0)
Host interface (CA#1)
Inlet
PSU switch
PSU FAIL LED
AC MISSING LED
POWER LED
FAN FAIL LED

Table of Contents

Other manuals for Fujitsu Eternus DX80 S2

Related product manuals