EasyManua.ls Logo

Fujitsu Eternus DX80 S2 - Installable Host Interfaces; Host Interface Handling Instructions; Figure 5.4 Installation Diagram for Host Interfaces (Dual-Controller Type)

Fujitsu Eternus DX80 S2
186 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 5 Maintaining Optional Products
5.3 Installing Host Interfaces
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation-
Copyright 2013 FUJITSU LIMITED P3AM-4842-12ENZ0
86
â–  For a dual-controller type
Figure 5.4 Installation diagram for host interfaces (dual-controller type)
5.3.2 Installable Host Interfaces
For installable host interfaces, refer to "Product List".
5.3.3 Host Interface Handling Instructions
â–  About condensation
â–  About static electricity
Expansion Expansion
Host interface (CA#1) Host interface (CA#1)
Controller 0 (CM#0)
Controller 1 (CM#1)
CAUTION
Do
• When moving a host interface from a cold place, such as an un-
conditioned store house in winter, to a warmer place such as an air-
conditioned room, the severe temperature change may result in
condensation forming.
To avoid this, allow the packed host interface sufficient time in the warmer
place (one hour for each 15°C of temperature difference) to adapt to the
new temperature.
CAUTION
Do
• When handling host interfaces, make sure to wear a wrist strap or touch a
metal part to discharge the human body's natural static electricity. Failure
to discharge static electricity may cause device failure.
• Leave the host interface in its package until ready to install it.

Table of Contents

Other manuals for Fujitsu Eternus DX80 S2

Related product manuals