Appendix A Event Notification Message List
A.2 Message List
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation-
Copyright 2013 FUJITSU LIMITED P3AM-4842-12ENZ0
136
J 11
SSMM
0
p
51100
MM
0
p
0CA Slot#
S
-
V
(
zz
) (on CM#
m
) Port#
P
Warning
<
pppppppppppp ssssssssss rrrrr
>
These messages are
notified when "Parts
Warning" is enabled
for Warning Level in
the event notification
setting.
They are not notified
during maintenance
operations.
CA port error is detected.
SS
: Component subtype
MM
: CA module ID (40 – 7F)
p:
Device port number (0 – 1)
S
: CA slot number (0 – 1)
V
: Device number (0 – 1)
zz: CA type
m
: CM number (0 – 1)
P
: Port number (0 – 1)
pp...
: Component number
ss...
: Serial number
rr...
: Version
J 21
SSMM
00 5 2100
MM
00 0 Controller Module#
m
(
zz
) FPGA Warning
<
pppppppppppp ssssssssss rrrrr
>
CA FPGA error is detected.
SS
: Component subtype
MM
: CM module ID (10 – 11)
m
: CM number (0 – 1)
zz
: Model name (DX80S2 or DX90S2)
pp...
: Component number
ss...
: Serial number
rr...
: Version
J 22
SSMM
0
p
52200
MM
0
p
0 Controller Module#
m
(
zz
) LAN PORT#
p
Warning
<
pppppppppppp ssssssssss rrrrr
>
CM LAN port error is detected.
SS
: Component subtype
MM
: CM module ID (10 – 11)
m
: CM number (0 – 1)
zz
: Model name (DX80S2 or DX90S2)
p
: Port number (0 – 1)
pp...
: Component number
ss...
: Serial number
rr...
: Version
J 7A000000 6 7A000000 1 CE Exhaust temperature Warning These messages are
notified when "Tem-
perature Warning" is
enabled for Warning
Level in the event
notification setting.
They are not notified
during maintenance
operations.
CE exhaust temperature error (Warning) is
detected.
J 7B000000 6 7B000000 1 CE Intake temperature Warning
CE intake temperature error (Warning) is detected.
Event type
code
SNMP Trap Upper: Message
Remarks
Trap
No.
TrapItemID (*1) Lower: Description