3-9
  
Problems
resolved
in
XCP
2230
SPARC
M10-
RTINo. 1 4 4S Description Worka rou nd
RTIF2-
140212-009
x
When
the
XSCF
is
under
high
load
due
to
high
volume
of
packets
sent
to
the
XSCF
network
by
the
L2
loop
etc.,
the
false
error
"Hardware
access
error"
regarding
the
power
unit
(PSU)
is
detected.
Moreover,
the
PSU
is
marked
as
failed
due
to
this
error.
If
the
reason
for
the
high
load
is
the
L2
loop,
eliminate
the
root
cause
by
reviewing
the
network
connection
etc.
[How
to
restore]
To
clear
the
failure
mark
on
PSU,
turn
off
the
input
power
and
then
turn
it
back
on.
RTIF2-
140527-001
xOn
a
system
that
is
configured
with
several
SPARC
M10-4S,
if
XSCF
rebooting
is
not
performed
with
the
rebootxscf(8)
command
or
if
the
input
power
is
not
turned
off
for
about
10
days
in
respect
to
the
XSCFs
of
the
following
status,
the
"XSCF
self-diagnosis
warning
detection"
error
message
is
logged:
-
A
standby
XSCF
which
did
not
perform
master/standby
switchover
for
about
10
days.
-
Slave
XSCF.
There
is
no
effective
workaround.
Please
ignore
this
message.
RTIF2-
140606-002
x x x Even
though
the
"AEV_
AUTHENTICATE"
audit
event
is
enabled,
XSCF
Web
login
failure
events
are
not
registered
in
the
audit
log.
There
is
no
effective
workaround.
RTIF2-
140606-003
xx xWhen
an
attempt
is
made
to
look
at
an
audit
log
concerning
XSCF
Web
operation
using
the
viewaudit(8)
command,
the
command
displays
incorrect
values.
The
displayed
values
of
the
port
number
and
IP
address
at
the
time
of
XSCF
Web
access
are
"0"
and
"0000".
There
is
no
effective
workaround.
RTIF2-
140606-006
xx xWhen
specifying
a
system
board
(PSB)
for
a
logical
system
board
(LSB)
on
the
[PPAR
Operation]
-
[PPAR
Configuration]
screen
of
XSCF
Web,
you
need
to
note
the
following:
A
PSB
cannot
be
specified
if
it
has
already
been
assigned
to
another
physical
partition
(PPAR).
For
the
setting,
use
the
setpcl(8)
command
of
the
XSCF
shell.
Chapter
3
 
Information
on
Software 91

Table of Contents

Other manuals for Fujitsu M10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu M10 and is the answer not in the manual?

Fujitsu M10 Specifications

General IconGeneral
BrandFujitsu
ModelM10
CategoryServer
LanguageEnglish

Related product manuals