Table
3-11
  
Problems
resolved
in
XCP
2220
(continued)
SPARC
M10-
RTI
No. 1 4 4S Description Workaround
RTIF2-
141106-002
xx xFor
XCP
2210
or
earlier,
the
error
log
"PCI
Express
link
up
failed"
may
be
erroneously
registered,
and
an
on-board
I/O
device
or
a
PCI
slot
may
be
degraded
if
a
physical
partition
(PPAR)
is
powered
on/off
after
any
of
the
following
error
logs
related
to
abnormal
temperature
is
registered.
-
Temperature
out
of
range
error
-
High
temperature
at
SW
-
Hardware
access
error.(thermal
sensor)
In
these
error
logs,
the
first
two
bytes
of
the
second
field
in
[Code:]
has
the
value
of
"0013".
There
is
no
effective
workaround.
[How
to
restore]
Turn
off
the
system
input
power,
then
restore
the
power
(AC-OFF/ON).
Table
3-12
  
Problems
resolved
in
XCP
2210
SPARC
M10-
RTI
No. 1 4 4S Description Workaround
RTIF2-
130801-002
xx If
a
DIMM
failure
occurs,
a
configuration
error
is
erroneously
detected
and
the
following
event
log
is
registered.
SCF:DIMM
configuration
error
on
PSB#xx-0
There
is
no
effective
workaround.
Ignore
this
event
log.
Using
the
maintenance
procedure
for
DIMM
failures,
turn
off
the
input
power
to
the
SPARC
M10
system
chassis
in
which
the
failed
DIMM
is
mounted,
replace
the
DIMM,
and
then
turn
on
the
power.
These
steps
will
remove
the
configuration
error
and
failure.
RTIF2-
131126-005
xx xThe
[Physical]
or
[Logical]
tree
displayed
in
the
menu
frame
is
not
updated
even
if
you
click
the
[Refresh]
button
of
the
masthead
frame
on
XSCF
Web.
Click
the
[Physical]
or
[Logical]
tab
of
the
menu
frame
to
redisplay
the
tree.
RTIF2-
131212-001
xIf
there
is
a
physical
partition
(PPAR)
whose
LSB
number
is
01
or
larger,
the
"showlogs
error"
command
either
does
not
show
the
"I/O
device
error
detected"
log
even
if
I/O
errors
occur,
or
the
FRU
in
the
"I/O
device
error
detected"
message
is
displayed
mistakenly.
There
is
no
effective
workaround.
Problems
resolved
in
XCP
2210
The
following
table
lists
the
problems
resolved
in
XCP
2210.
Fujitsu
M10/SPARC
M10
Systems
Product
Notes
for
XCP
Version
2240
March
2015106

Table of Contents

Other manuals for Fujitsu M10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu M10 and is the answer not in the manual?

Fujitsu M10 Specifications

General IconGeneral
BrandFujitsu
ModelM10
CategoryServer
LanguageEnglish

Related product manuals