EasyManuals Logo

Fujitsu M10 Product Notes

Fujitsu M10
216 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #154 background imageLoading...
Page #154 background image
Table
3-19
  
Problems
resolved
in
XCP
2051
SPARC
M10-
RTI
No. 1 4 4S Description Workaround
RTIF2-
130717-001
xx xIf
an
error
occurs
in
the
USB-SSD
in
the
XSCF
interface
unit
(XSCFIFU)
of
the
PSU
backplane
(PSUBP)
or
crossbar
box,
the
"System
backup
memory
access
error"
error
log
may
be
registered.
In
this
case,
a
problem
such
as
the
inability
to
execute
the
poweron(8)
command
or
the
inability
to
collect
data
with
the
snapshot(8)
command
may
occur.
There
is
no
effective
workaround.
When
this
problem
occurs,
power
off
the
input
power
supply
and
then
power
it
on
again
(AC
OFF/ON).
Table
3-20
  
Problems
resolved
in
XCP
2050
SPARC
M10-
RTI
No. 1 4 4S Description Workaround
RTIF2-
130219-002
x
When
maintaining
SPARC
M10-4S
with
a
slave
XSCF,
if
you
incorrectly
connect
the
standby
XSCF
and
the
slave
XSCF
with
an
XSCF
connection
cable,
the
maintenance
is
considered
to
have
finished
normally
without
detecting
the
error.
After
switching
between
the
master
XSCF
and
the
standby
XSCF
by
using
the
switchscf(8)
command,
execute
the
testsb(8)
command
to
the
target
slave
XSCF.
The
incorrect
connection
with
the
XSCF
connection
cable
is
detected
and
an
error
log
is
issued.
RTIF2-
130305-016
x Timeout
may
occur
if
the
XCP
firmware
version
of
a
SPARC
M10-4S
or
crossbar
box
is
updated
using
the
flashupdate
-c
sync
command.
Execute
the
flashupdate(8)
command
by
specifying
the
-f
option
to
reupdate
the
XCP
firmware
for
all
SPARC
M10-4S
or
crossbar
boxes.
RTIF2-
130319-002
xx x
Before
power-off
of
the
physical
partition
(PPAR)
completes
in
SPARC
M10-4S,
if
you
power
off
and
then
power
on
the
input
power
supply
of
a
SPARC
M10-4S
or
a
crossbar
box
again
and
power
on
the
PPAR
again,
the
PPAR
in
operation
may
be
powered
off
if
the
master
XSCF
is
switched
with
the
switchscf(8)
command,
firmware
update,
or
failure.
If
you
power
off
the
PPAR
before
powering
off
the
input
power
supply
of
SPARC
M10-4S
or
crossbar
box,
check
that
power-off
the
target
PPAR
and
SPARC
M10-4S
is
complete,
by
using
the
showboards(8)
and
showlogs
power
commands.
Then,
power
off
the
input
power
supply
of
SPARC
M10-4S
or
crossbar
box.
Problems
resolved
in
XCP
2050
The
following
table
lists
the
problems
resolved
in
XCP
2050.
Fujitsu
M10/SPARC
M10
Systems
Product
Notes
for
XCP
Version
2240
March
2015140

Table of Contents

Other manuals for Fujitsu M10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu M10 and is the answer not in the manual?

Fujitsu M10 Specifications

General IconGeneral
BrandFujitsu
ModelM10
CategoryServer
LanguageEnglish

Related product manuals