Notes
and
Restrictions
This
section
describes
notes
and
restrictions
that
are
known
as
of
this
release.
Notes
on
Secure
Socket
Layer
(SSL)
3.0
For
security
reasons,
you
cannot
use
SSL
3.0
with
XCP
2240
or
later.
Use
Transport
Layer
Security
(TLS)
1.0.
Restrictions
on
audit
The
log
file
transfer
function
of
the
audit
log
set
with
the
setaudit
archive
command
and
the
setaudit
disable
command
is
not
supported
at
present.
If
the
policy
for
writing
to
an
audit
record
is
set
to
stop
temporarily
("suspend"),
degradation
due
to
an
error
may
occur
or
the
XSCF
may
be
reset.
In
the
setaudit(8)
command,
specify
overwriting
("count")
by
default
for
the
write
policy
for
the
audit
trail.
For
details
of
this
problem,
see
"RTIF2-141208-001."
Notes
on
dynamic
reconfiguration
of
physical
partitions
In
case
of
dynamic
reconfiguration
of
physical
partitions,
when
adding
an
I/O
device,
it
is
necessary
to
either
stop
the
domain
or
use
the
delayed
reconfiguration
feature
to
integrate
the
I/O
device
into
the
logical
domain,
after
executing
the
addboard(8)
command.
Moreover,
when
removing
an
I/O
device,
after
removing
the
I/O
device
by
stopping
the
domain
or
using
the
delayed
reconfiguration
feature,
execute
the
deleteboard(8)
command
in
order
to
disconnect
the
system
board.
For
details
on
each
procedure,
refer
to
the
Fujitsu
M10/SPARC
M10
Systems
Domain
Configuration
Guide.
Note
that
you
can
add
and
delete
I/O
devices
without
stopping
the
logical
domains
and
without
delayed
reconfiguration
on
Oracle
Solaris
11.2
SRU11.2.8
or
later.
After
dynamic
reconfiguration
of
a
physical
partition,
the
execution
results
of
prtdiag(1M)
command
executed
from
the
control
domain
may
differ
from
the
actual
physical
configuration.
Executing
"svcadm
restart
picl"
can
update
to
the
latest
information.
While
adding
or
removing
system
boards
with
the
addboard(8)
or
deleteboard(8)
command
of
the
DR
feature,
do
not
reboot
all
the
XSCFs
with
either
the
"rebootxscf
-a"
command
or
from
the
XSCF
Web
interface.
If
such
an
operation
is
Fujitsu
M10/SPARC
M10
Systems
Product
Notes
for
XCP
Version
2240
March
201512

Table of Contents

Other manuals for Fujitsu M10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu M10 and is the answer not in the manual?

Fujitsu M10 Specifications

General IconGeneral
BrandFujitsu
ModelM10
CategoryServer
LanguageEnglish

Related product manuals