EasyManuals Logo

Fujitsu M10 Product Notes

Fujitsu M10
216 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #129 background imageLoading...
Page #129 background image
Table
3-13
  
Problems
resolved
in
XCP
2092
SPARC
M10-
RTI
No. 1 4 4S Description Workaround
RTIF2-
131213-015
xIn
case,
all
of
the
three
conditions
below
are
met
on
a
physical
partition,
the
crossbar
unit
(XBU)
error
"Msg:
XB-XB
interface
fatal
error"
is
detected.
[Condition
1]
The
physical
partition
is
configured
by
several
SPARC
M10-4S.
[Condition
2]
The
XSCF
BB
control
cables
that
are
connected
to
the
SPARC
M10-4S
chassis
are
either
defective
or
have
been
disconnected.
In
such
a
case,
the
"Msg:
BB
control
cable
detected
unexpected"
error
log
is
registered.
[Condition
3]
The
physical
partition
was
rebooted
due
to
a
hardware
failure,
the
poweron(8)
or
reset(8)
command
was
executed.
Moreover,
XSCF
had
either
rebooted
the
physical
partition
due
to
a
hardware
failure
or
had
performed
retrial
of
the
poweron(8)
or
the
reset(8)
command
when
this
symptom
occurred
previously.
There
is
no
effective
workaround.
Do
not
execute
the
poweron(8)
or
the
reset(8)
command
while
the
XSCF
BB
control
cable
is
disconnected.
[How
to
restore]
If
hardware
failure
had
occurred,
execute
power
off
and
on,
on
the
physical
partition.
If
XSCF
is
performing
retrial
operations,
execute
the
"poweroff
-f
-p
ppar-id"
command
to
forcibly
power
off
the
physical
partition.
After
that
power
it
on.
RTIF2-
140110-001
xIn
a
SPARC
M10-4S
(with
crossbar
box)
configuration,
the
following
event
log,
which
notifies
power
off,
is
not
registered.
BB#xx
was
stopped
by
power
failure.
Power
failure
date
is
yyyy/mm/dd
hh:mm:ss
There
is
no
effective
workaround.
RTIF2-
140110-002
xx xWhen
the
flashupdate(8)
command
is
executed,
only
occasionally,
XSCF
may
not
start-up.
There
is
no
effective
workaround.
Contact
a
field
engineer
if
this
problem
occurs.
RTIF2-
140115-001
xx xIf
a
failure
occurs
in
the
PCI
Expansion
Unit,
all
the
domains
that
are
situated
in
the
physical
partition
(PPAR)
that
is
connected
to
the
PCI
Expansion
Unit,
are
shut
down.
There
is
no
effective
workaround.
Problems
resolved
in
XCP
2091
The
following
table
lists
the
problems
resolved
in
XCP
2091.
Chapter
3
 
Information
on
Software 115

Table of Contents

Other manuals for Fujitsu M10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu M10 and is the answer not in the manual?

Fujitsu M10 Specifications

General IconGeneral
BrandFujitsu
ModelM10
CategoryServer
LanguageEnglish

Related product manuals