EasyManuals Logo

Fujitsu M10 Product Notes

Fujitsu M10
216 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #127 background imageLoading...
Page #127 background image
Table
3-12
  
Problems
resolved
in
XCP
2210
(continued)
SPARC
M10-
RTI
No. 1 4 4S Description Workaround
RTIF2-
140407-007
x After
a
degraded
system
board
is
replaced
using
the
replacefru(8)
command,
the
replacement
system
board
is
diagnosed
using
the
replacefru(8)
command
menu
or
the
testsb(8)
command.
The
diagnosis
fails
if
all
of
the
following
conditions
are
met.
-
Physical
partition
(PPAR)
consists
of
multiple
system
boards
and
the
PPAR
power
is
on.
-
Some
system
boards
in
the
PPAR
are
stopped
through
degradation.
Use
either
of
the
following
procedures
to
replace
a
system
board
and
execute
diagnosis.
1.
Before
replacing
the
system
board,
execute
the
deleteboard(8)
command
to
change
the
system
board
state
to
system
board
pool
(SP).
2.
After
completing
system
board
replacement
and
diagnosis,
execute
the
addboard(8)
command
to
assign
the
system
board
to
PPAR
again.
Or
1.
After
powering
off
the
PPAR,
execute
system
board
replacement
and
diagnosis.
[How
to
restore]
After
executing
the
deleteboard(8)
command
to
change
the
system
board
state
to
system
board
pool
(SP)
or
after
powering
off
the
PPAR,
redo
the
system
board
diagnosis.
RTIF2-
140410-001
xx xAn
XSCF
NTP
server
function
may
be
used
as
the
platform
for
a
DDoS
attack
(CVE-2013-5211).
Update
the
XCP
firmware
version
to
XCP
2210
or
later.
RTIF2-
140410-007
xWhen
setting
the
takeover
IP
address
(virtual
IP
address)
for
the
XSCF
network,
the
XSCF-LAN
IP
address
(physical
IP
address)
needs
to
be
set
for
both
master
and
standby
XSCFs.
Otherwise,
the
takeover
IP
address
setting
may
not
be
reflected
after
the
setting
is
applied
and
XSCF
is
reset.
Set
the
XSCF-LAN
IP
address
(physical
IP
address)
of
both
master
and
standby
XSCFs
and
then
set
the
takeover
IP
address.
RTIF2-
140507-
019
xx xIf
Firefox
26
is
used
in
an
environment
with
XSCF
firmware
older
than
XCP
2210,
the
frame
of
the
pop-up
window
appears
in
thick
black
line.
Ignore
the
thick
black
frame.
RTIF2-
140507-020
x
If
the
master
XSCF
is
switched
to
standby
state
just
after
executing
the
"poweroff
-f
-p
-n"
(n
is
partition
number)
command,
the
following
message
is
registered
in
the
error
log,
displayed
by
the
"showlogs
error"
command.
Msg:
SCF
process
down
detected
There
is
no
effective
workaround.
This
symptom
has
no
effect
on
the
system
operation.
Chapter
3
 
Information
on
Software 113

Table of Contents