3-21
  
Problems
resolved
in
versions
prior
to
XCP
2050
(continued)
SPARC
M10-
RTI
No. 1 4 4S Description Workaround
RTIF2-
121113-009
x x x While
XSCF
is
running,
process
down,
panic
or
watchdog
timeout
occurs,
which
may
cause
XSCF
not
to
be
restarted
after
XSCF
reset.
Confirm
that
XSCF
is
successfully
started.
If
it
is
not
started,
turn
off
the
power
of
the
physical
partition
(PPAR),
and
then
disconnect
the
input
power
supply
to
the
system
and
back
on
again
(AC
OFF/ON).
When
recycling
the
power
supply
to
the
system,
wait
for
30
seconds
or
more
to
turn
on
the
input
power
supply
after
disconnecting.
In
case
XSCF
is
not
started
even
if
recycling
the
input
power
supply
to
the
system,
replace
the
CPU
memory
unit
lower
(CMUL)
or
the
motherboard
unit
(MBU).
RTIF2-
121113-011
xx xIf
you
execute
the
showsnmp(8)
command,
the
following
message
may
appear,
which
means
that
the
snmp
daemon
has
been
terminated.
Agent
Status:
Disabled
Execute
the
showsnmp(8)
command
again
to
confirm
that
the
snmp
daemon
is
restarted.
If
"Agent
Status:
Disabled"
remains
displayed,
execute
the
setsnmp
enable
command
to
restart
the
snmp
daemon.
RTIF2-
121113-014
xx xThe
error
message
"/etc/redhat-release
not
found"
appears
while
XSCF
is
starting.
Ignore
this
message.
RTIF2-
121113-018
x x x When
you
replace
an
FRU
with
the
replacefru(8)
command,
the
message
"configuration
changed
(...)"
showing
the
configuration
change
may
be
registered
more
than
once
in
the
event
log.
Ignore
the
message
that
appears
second
time
and
later.
RTIF2-
121113-019
x x x When
the
power
supply
of
the
physical
partition
(PPAR)
is
disconnected
according
to
the
power
supply
schedule,
"-"
may
be
displayed
as
the
cause
(Cause)
in
the
power
log.
There
is
no
effective
workaround.
RTIF2-
121113-021
xx x
If
time
cannot
be
read
accurately
due
to
a
failed
clock
in
the
XSCF
board,
an
error
showing
a
clock
failure
may
not
be
recorded
in
the
error
log.
There
is
no
effective
workaround.
If
the
following
message
appears
when
you
execute
the
poweron(8)
command,
the
clock
in
the
XSCF
board
has
failed.
Replace
the
XSCF
board.
Poweron
canceled
due
to
invalid
system
date
and
time.
RTIF2-
121113-022
xx xIf
the
operation
panel
has
failed
or
is
not
connected,
XSCF
cannot
be
started.
Connect
the
operation
panel.
If
the
operation
panel
has
failed,
replace
it.
RTIF2-
121113-023
RTIF2-
121113-028
xx xIf
a
CPU
failure
occurs
while
Hypervisor
is
running,
the
physical
partition
(PPAR)
is
reset
more
than
once,
and
restarting
of
the
PPAR
may
take
time.
There
is
no
effective
workaround.
Fujitsu
M10/SPARC
M10
Systems
Product
Notes
for
XCP
Version
2240
March
2015146

Table of Contents

Other manuals for Fujitsu M10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu M10 and is the answer not in the manual?

Fujitsu M10 Specifications

General IconGeneral
BrandFujitsu
ModelM10
CategoryServer
LanguageEnglish

Related product manuals