3-21
  
Problems
resolved
in
versions
prior
to
XCP
2050
(continued)
SPARC
M10-
RTI
No. 1 4 4S Description Workaround
RTIF2-
130219-008
xIf
you
turn
on
the
input
power
supply
to
a
SPARC
M10-4S
chassis
while
a
physical
partition
(PPAR)
is
being
powered
on
in
a
system
that
has
multiple
PPARs,
the
SPARC
M10-4S
chassis
for
which
the
input
power
supply
is
turned
on
may
not
be
recognized
by
the
master
XSCF.
Power
on
the
input
power
supply
to
all
the
crossbar
boxes
and
SPARC
M10-4S
chassis
that
compose
the
system
before
powering
on
a
PPAR.
RTIF2-
130227-001
xIf
you
collect
a
snapshot
by
specifying
the
-a
option,
"XSCF
Kernel
Panic"
may
occur
due
to
the
increased
load
on
the
master
XSCF.
If
you
collect
a
snapshot
of
the
entire
system,
collect
snapshots
one
by
one
by
specifying
a
BB-ID
of
SPARC
M10-4S
using
-b
option
and
not
-a
option.
Perform
this
operation
on
all
SPARC
M10-4S.
RTIF2-
130305-005
xIf
XSCF
panic
occurs
in
a
SPARC
M10-4S
while
processing
the
diagnose
by
the
POST
after
a
physical
partition
(PPAR)
is
powered
on
in
the
system
that
has
more
than
one
SPARC
M10-4S
chassis,
then
the
power
may
be
disconnected
without
continuing
the
process
of
powering
on
the
PPAR.
There
is
no
effective
workaround.
Make
sure
that
the
XSCF
of
each
SPARC
M10-4S
is
restarted.
Power
on
the
PPAR
again
if
they
are
restarted.
RTIF2-
130305-008
xIf
each
physical
partition
(PPAR)
is
configured
with
one
system
board
(PSB)
in
the
system
that
has
more
than
one
SPARC
M10-4S
chassis
and
crossbar
box,
the
power
of
the
crossbar
unit
of
a
crossbar
box
is
not
stopped
and
the
crossbar
box
is
also
powered
on.
There
is
no
effective
workaround.
RTIF2-
130305-010
x Hypervisor
Abort
or
OS
PANIC
may
occur
if
all
the
PPARs
are
powered
on
using
the
poweron
-a
command
in
a
system
that
has
four
or
more
SPARC
M10-4S
chassis
units
with
multiple
physical
partitions
(PPARs).
Do
not
power
on
all
the
PPARs
at
the
same
time
using
the
poweron
-a
command.
Power
on
each
PPAR
using
the
-p
option.
RTIF2-
130305-021
x Immediately
after
starting
the
XSCF,
the
system
board
(PSB)
may
be
recognized
as
"Unmount"
and
the
addboard(8)
command
or
the
poweron(8)
command
may
fail.
Wait
for
about
30
seconds
after
starting
up
the
XSCF
and
check
that
the
target
PSB
is
mounted
using
the
showboards(8)
command.
Then
execute
the
addboard(8)
or
poweron(8)
command.
Fujitsu
M10/SPARC
M10
Systems
Product
Notes
for
XCP
Version
2240
March
2015154

Table of Contents

Other manuals for Fujitsu M10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu M10 and is the answer not in the manual?

Fujitsu M10 Specifications

General IconGeneral
BrandFujitsu
ModelM10
CategoryServer
LanguageEnglish

Related product manuals