3-21
  
Problems
resolved
in
versions
prior
to
XCP
2050
(continued)
SPARC
M10-
RTI
No. 1 4 4S Description Workaround
RTIF2-
130507-001
xx xThere
is
a
case
where
a
RAID
volume
cannot
be
recognized
after
a
power
failure
occurred
while
using
the
hardware
RAID
function.
Please
run
the
activate-volume
command
at
ok
prompt
to
activate
a
hardware
RAID
volume.
For
the
detailed
procedure,
see
"12.2.8
Re-enabling
hardware
RAID
volume"
in
the
Fujitsu
M10/SPARC
M10
Systems
System
Operation
and
Administration
Guide
.
RTIF2-
130515-001
x x x While
the
system
is
operating,
the
following
events
may
occur:
1.
The
prtpicl
command
no
longer
responds.
2.
Display
data
(such
as
the
XCP
version)
of
prtpicl
-v
and
prtdiag
-v
is
not
output
as
expected.
3.
For
/var/adm/messages,
the
warning
message,
"PICL
snmpplugin:
cannot
fetch
object
value",
is
output.
4.
XSCF
CMDD
process
shutdown
occurs
and
an
XSCF
is
reset
repeatedly,
such
that
it
becomes
unusable.
At
this
time,
system
operation
can
be
continued.
There
is
no
effective
workaround.
[How
to
restore]
-
If
event
1
occurs:
Recover
with
the
following
procedure.
1.
End
the
prtdiag(1M)
command
with
[Ctrl]
+
[C].
2.
Wait
for
about
30
minutes,
and
allow
an
SNMP
timeout
to
occur
in
the
XSCF.
3.
In
the
control
domain,
execute
the
svcadm(1M)command
to
restart
the
picl
service.
-
If
event
2
occurs:
Execute
the
command
again.
If
results
are
displayed,
the
system
can
be
operated
continuously.
If
the
state
where
results
are
not
displayed
as
expected
continues,
check
whether
the
XSCF
is
operating.
-
If
the
XSCF
is
operating,
use
the
rebootxscf(8)
command
to
reset
the
XSCF.
-
If
the
XSCF
is
not
operating,
turn
the
input
power
supply
of
the
system
off
and
then
back
on
(AC
OFF/ON)
to
recover.
-
If
event
3
occurs:
The
system
can
be
operated
continuously
because
this
is
a
temporary
warning
message.
-
If
event
4.
occurs:
Turn
off
the
input
power
supply
of
the
system,
and
then
back
on
(AC
OFF/ON)
to
recover.
RTIF2-
130516-005
xx xIf
the
showcodactivation(8)
command
is
executed
while
data
is
being
restored
with
the
restoreconfig(8)
or
restorecodactivation(8)
command,
it
may
be
impossible
to
display
the
execution
results.
If
this
occurs,
the
showcodactivation(8)
command
ends
with
a
"codd
internal
error".
The
execution
results
can
be
displayed
if
the
showcodactivation(8)
command
is
executed
after
the
execution
of
the
restoreconfig(8)
or
restorecodactivation
(8)
command
is
completed.
Fujitsu
M10/SPARC
M10
Systems
Product
Notes
for
XCP
Version
2240
March
2015158

Table of Contents

Other manuals for Fujitsu M10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu M10 and is the answer not in the manual?

Fujitsu M10 Specifications

General IconGeneral
BrandFujitsu
ModelM10
CategoryServer
LanguageEnglish

Related product manuals