EasyManuals Logo

Fujitsu M10 Product Notes

Fujitsu M10
216 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #210 background imageLoading...
Page #210 background image
Table
7-4
  
Problems
resolved
in
version
1150
of
the
PCI
expansion
unit
firmware
(continued)
SPARC
M10-
RTI
No. 1 4 4S Description Workaround
RTIF2-
131224-002
x x x When
the
PCI
Expansion
Unit
and
the
chassis
of
SPARC
M10
system
are
connected
by
optical
cables
in
a
low-temperature
environment,
optical
cable
error
logs
may
be
registered.
This
symptom
can
be
confirmed
by
the
"showlogs
error
-v"
command.
If
the
result
of
the
"showlogs
error
-v"
command
is
"Msg:
LINKCBL
failed",
and
the
3rd
byte
of
the
4th
line
of
the
"Diagnostic
Code"
is
either
"10",
"50"
or
"60",
it
corresponds
to
this
symptom.
[Example
of
the
error
message]
In
case
the
3rd
byte
of
the
4th
line
of
the
"Diagnostic
Code"
is
"10":
XSCF>
show logs
error
-v
Date:
Dec
17
15:50:11
JST
2013
Code:
10000400-
009eff0000ff0000ff-
110000440000000000000000
Status:
Information
Occurred:
Dec
17
15:50:06.930
JST
2013
FRU:
/BB#0/PCI#3/LINK/
LINKCBL#1
Msg:
LINKCBL
failed
Diagnostic
Code:
00030001
00000000
0000
00030000
00000000
0000
00030000
00000000
0000
00001000
00000000
00000000
00000000
00000000
00000000
0000
Ignore
this
error
message
as
it
has
no
effect
on
the
system.
Problems
resolved
in
version
1130
of
the
PCI
expansion
unit
firmware
The
following
table
lists
the
problems
resolved
in
version
1130
of
the
PCI
expansion
unit
firmware.
Fujitsu
M10/SPARC
M10
Systems
Product
Notes
for
XCP
Version
2240
March
2015196

Table of Contents

Other manuals for Fujitsu M10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu M10 and is the answer not in the manual?

Fujitsu M10 Specifications

General IconGeneral
BrandFujitsu
ModelM10
CategoryServer
LanguageEnglish

Related product manuals