supported.
â– 
Alive
monitoring
between
the
XSCF
and
a
Hypervisor
is
not
supported.
Alive
monitoring
between
the
XSCF
and
a
Hypervisor
cannot
be
enabled/disabled
even
by
using
the
setpparmode(8)
command.
â– 
[SPARC
M10-4S]
Suppose
that
the
XSCF
was
switched
while
connecting
to
the
control
domain
console
in
the
SPARC
M10-4S
that
is
composed
of
more
than
two
chassis.
In
that
case,
connection
to
the
control
domain
console
may
not
be
established
until
all
the
SPARC
M10-4S
chassis
have
been
restarted
if
an
attempt
has
been
made
to
reconnect
the
control
domain
console
to
the
switched
master
XSCF.
If
all
XSCFs
have
not
been
restarted
due
to
an
error
in
the
XSCF,
establish
a
connection
to
the
control
domain
console
again.
Replace
a
failed
XSCF
or
CPU
memory
unit
lower
(CMUL)
if
a
connection
cannot
be
established
to
the
control
domain
console.
â– 
[SPARC
M10-4S]
The
poweroff(8)
and
reset(8)
commands
may
not
be
executed
normally
if
all
XSCF
have
not
been
restarted
due
to
an
error
in
a
XSCF
in
the
SPARC
M10-4S
that
is
composed
of
more
than
two
chassis.
To
disconnect
the
power
of
a
physical
partition
(PPAR),
login
to
the
control
domain
of
the
PPAR
and
execute
the
shutdown(1M)
command
on
Oracle
Solaris.
Then,
disconnect
the
power
of
the
PPAR
using
the
poweroff
-f
command
on
the
XSCF
firmware.
The
reset(8)
command
cannot
be
used
in
this
state.
â– 
The
-c
wait
option,
which
is
used
to
set
the
wait
time
before
the
system
is
started
for
the
setpowerupdelay(8)
command,
is
not
supported
at
present.
â– 
Replacement
of
a
crossbar
box
using
the
replacefru(8)
command
is
not
supported
at
present.
For
how
to
replace
a
crossbar
box,
see
"Restrictions
on
replacing
crossbar
box"
in
"Chapter
6
Information
on
SPARC
M10-4S
Hardware."
â– 
Addition
of
a
crossbar
box
using
the
addfru(8)
command
is
not
supported
at
present.
For
how
to
add
a
crossbar
box,
see
"Restrictions
on
adding
expansion
rack
2"
in
"Chapter
6
Information
on
SPARC
M10-4S
Hardware."
â– 
[SPARC
M10-4S]
If
you
power
on
all
physical
partitions
(PPAR)
in
a
system
that
has
more
than
one
PPARs
with
the
poweron(8)
command,
the
startup
time
taken
when
specifying
power-on
of
PPAR
is
longer
than
the
time
taken
for
batch
power-on
by
specifying
-a.
â– 
[SPARC
M10-4/M10-4S]
As
for
the
ioreconfigure
that
can
be
specified
by
-m
function
of
the
setpparmode
(8)
command,
leave
it
as
the
default,
false,
and
disable
the
I/O
bus
reconfiguration
function.
If
you
enable
the
I/O
bus
reconfiguration
function
by
specifying
true
to
the
ioreconfigure,
it
may
be
necessary
to
reinstall
Oracle
Solaris.
â– 
[SPARC
M10-4S]
If
showhardconf
-M
is
executed,
it
may
not
be
possible
to
display
one
screen
at
a
time
if
both
of
the
conditions
below
are
met.
Do
not
execute
showhardconf
-M.
-
System
configured
with
2BB
or
more
-
One
or
more
SPARC
M10-4S
units
are
subject
to
an
XSCF
reset
by
the
Chapter
2
 
XCP
2240-Related
Information 31