3-5
  
Problems
that
might
occur
with
XCP
2240
and
workarounds
(continued)
SPARC
M10-
RTI
No. 1 4 4S Description Workaround
RTIF2-
131213-002
xWhile
in
the
process
of
adding
or
removing
a
system
board
(PSB)
using
the
addboard(8)
or
deleteboard(8)
command
of
the
DR
feature,
if
another
physical
partition
is
rebooted
due
to
hardware
failure
or
the
poweroff(8)/poweron(8)/
reset(8)
command
is
executed
on
it,
the
executed
addboard(8)
or
deleteboard(8)
command
may
detect
timeout
and
terminate
abnormally.
Do
not
execute
the
poweroff(8)/poweron
(8)/reset(8)
command
while
the
addboard(8)
or
deleteboard(8)
command
is
being
executed.
There
is
no
effective
workaround
if
any
hardware
failure
occurs
while
executing
DR.
[How
to
restore]
Check
the
status
of
the
system
board
(PSB)
using
the
showboards(8)
command.
Execute
the
addboard(8)
or
deleteboard
(8)
command
after
that.
RTIF2-
131213-003
xWhile
executing
the
poweroff(8)/
poweron(8)/reset(8)
command
on
a
physical
partition,
if
the
addboard(8)
or
the
deleteboard(8)
command
of
the
DR
feature
is
executed
on
another
physical
partition
to
add
or
remove
a
system
board
(PSB),
the
addboard(8)
or
deleteboard(8)
command
may
detect
timeout
and
terminate
abnormally.
Do
not
execute
the
addboard(8)
or
deleteboard(8)
command
while
the
poweroff(8)/poweron(8)/reset(8)
command
is
being
executed
elsewhere.
There
is
no
effective
workaround
if
DR
is
executed
while
also
executing
power
supply
operations
on
another
physical
partition.
[How
to
restore]
Execute
the
following:
1.
Execute
the
showboards(8)
command.
2.
Check
the
status
of
/Pwr/Conn/Conf/
Test
of
the
system
board
(PSB)
to
confirm
the
end
of
power
operations.
-
End
of
power-on/reset:
The
status
of
Pwr/Conn/Conf/Test
is
"y
y
y
passed"
respectively.
-
End
of
power-off:
The
status
of
Pwr/Conn/Conf
is
"n
n
n"
respectively
3.
Re-execute
the
addboard(8)
or
the
deleteboard(8)
command.
RTIF2-
131213-010
xx x
When
the
firmware
of
the
PCI
Expansion
Unit
is
updated
with
the
"ioxadm
–c
update"
command,
process
down
may
occur
at
the
XSCF
firmware.
There
is
not
effective
workaround.
Re-execute
the
"ioxadm
–c
update"
command
to
update
the
PCI
Expansion
Unit
firmware
again.
Chapter
3
 
Information
on
Software 47

Table of Contents

Other manuals for Fujitsu M10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu M10 and is the answer not in the manual?

Fujitsu M10 Specifications

General IconGeneral
BrandFujitsu
ModelM10
CategoryServer
LanguageEnglish

Related product manuals