Table
3-5
  
Problems
that
might
occur
with
XCP
2240
and
workarounds
(continued)
SPARC
M10-
RTI
No. 1 4 4S Description Workaround
partitio
n
is
active
(the
status
is
ot
h
er
than
"Powered
Off").
-
You
can
access
XSCF,
but
the
execution
result
of
the
showlogs
power
command
does
not
include
"SCF
Reset"
indicating
that
XSCF
is
reset.
*1:
If
a
power
failure
notification
is
issued,
usually
the
following
log
is
registered
by
the
showlogs
event
command.
PSU
input
power
failure(/PSU#0)
PSU
input
power
failure(/PSU#1)
In
addition,
the
following
error
log
is
detected
in
many
cases
when
the
trouble
in
[1]
occurs:
failed
to
read/write
extended
active
status
register
Do

you

want

to

continue?[r:replace|c:cancel]

:
r
Please

execute

the

following

steps:
1)

Remove

PSU#n.
2)

Execute

either

the

following:

2-1)

After

installing

the

exchanged

device,

please

select

'finish'.

2-2)

If

you

want

to

suspend

the

maintenance

without

exchanging

device,

please

select

'cancel'.
[f:finish|c:cancel]

:
f
Maintenance/Replacement

Menu

Please

select

a

FRU

to

be

replaced.
No.

FRU

Status

---

-------------------

--------------

1

/PSU#0

Deconfigured

2

/PSU#1

Deconfigured

------------------------------------------------------------------------------

Select

[1,2|b:back]

:
2
[Warning:307]

PSU#1

cannot

be

replaced.

Please

verify

the

configuration.

Select

[1,2|b:back]

:
2
[Warning:307]

Workaround
for
RTIF2-140304-007
If
PSU
is
replaced
by
the
replacefru(8)
command,
after
mounting
the
new
PSU,
wait
for
at
least
30
seconds
before
pressing
the
[f]
key
of
the
menu
of
replacefru(8)
command.
[How
to
restore]
If
both
PSUs
become
"Deconfigured"
without
performing
workarounds,
active
replacement
of
the
PSUs
cannot
be
done
with
the
replacefru(8)
command.
Fujitsu