72 Operating Manual RX200 S6
Starting up and operation
System already installed:
Ê Press the On/Off button (item 5 in figure 12 on page 61).
Power-on indicator (item 6 in figure 12 on page 61) lights green.
The server is switched on, performs a system test and boots the
operating system.
Switching the server off
Power-on indicator (item 10 in figure 12 on page 61) lights green.
Ê Shut down the operating system properly.
The server is switched off automatically and goes into standby mode. The
power-on indicator lights up orange.
I If the operating system does not switch the server off automatically, press
the On/Off button for at least four seconds and/or send a corresponding
control signal for power button override.
Other On/Off options
Besides the On/Off button, the server can be switched ON and OFF in the
following ways:
Timer-controlled switch-on/off
Using the ServerView Operations Manager or iRMC S2, you can configure
that the server is switched on/off controlled by timer.
Ring indicator
The server is switched on by an internal or external modem.
Wake up On LAN (WOL)
The server is switched on by a command via the LAN (Magic Packet
TM
).
After power failure
The server automatically reboots following a power failure (depending on the
settings in the BIOS or in iRMC S2).