RX300 S5 Service Supplement 41
Replacement routines Replacing the IDTemp Combo
4.7 Replacing the IDTemp Combo
This board includes two important system components:
EEPROM for the chassis ID and Ident number of the server
temperature sensor for monitoring the environmental temperature
The data for the EEPROM, and the current temperature values as well, are
transmitted to the system board via the connected I
2
C bus.
The IDTEMP combo must be correctly installed in order to monitor the temper-
ature correctly, enable ServerView to display the correct system picture and to
install the server using ServerStart.
Ê Open the server as described in the section “Preparation” on page 17.
Ê Remove the fan box (see Option Guide PRIMERGY RX300 S5 in the
chapter „preparations“).
Figure 30: Removing IDTemp Combo with holder