Telnet Interface Management Agent
ServerView BX900 Management Blade 19
3.3.3 System Information
The System Information option provides information on all components of the blade server management system,
such as power supply, fans, temperature,
KVM (= keyboard/video/mouse).
The menu for this option looks like this:
Figure 6: System Information menu
The menu offers the following subordinate options to the user:
Management Blade Asset Tag Sets a unique asset tag for the management blade.
Parameter Description
System Control Information Displays the number of system fans, power supply groups and temperature
sensors, as well as the status of all system components, excepting CPU blades
and connection blades.
System Power Supply Displays information on the power supply units.
System Fan Displays information on the number and status of the system fans, including
parameters like nominal speed, current speed, speed threshold and failure
reaction. A fan test is also provided, supporting the fan life time monitor.
System Temperature Displays information on the system temperature, including current value,
warning level, critical level, sensor status and critical temperature reaction.
System Chassis Table Displays information on the system chassis, including the chassis serial number
and if there has been any intrusion into the inside of the chassis.
System UPS Displays chassis UPS (uninterruptable power supply) information, including
UPS number, vendor, type, IP address, connect port, and SNMP community.
ID LED Control Displays the status of the system control: on, off, or blinking.
NIC Status Detection In dual MMB mode the roles are switched when the LAN connection to the
master fails, and the slave takes over the role of the master.
Turn on/off all server blades Turns on or turns off all server blades.
Automatic Inventory Retrieval The function is only working for VIOM. If set to automatic, the inventory retrieval
is automatically performed for inserted server blades or when the basic unit is
powered on. If set to manual, the automatic inventory retrieval is not done.