ServerView BX900 Management Blade 31
Figure 15: Set System Default menu
The following parameters can be set:
3.3.11 Server Blade CMOS Backup/Restore
I
This function supports S1 and S2 server blades only.
This option is used to backup and restore server blade BIOS parameters. The server blade must be powered on
before backup/restore processing. If the backup is successful, the backup file will be displayed in the CMOS
backup file table.
After selecting the server blade whose BIOS is to be backed up or whose backup file is to be restored, the Server
CMOS Configure option is displayed:
Figure 16: Server CMOS Configure menu
Parameter Description
Set Config Default The configuration of the management blade is set to the default values.
V Please note that all configured values are lost and the management
blade has to be configured newly after using this option.
Set Username/Password Default All configured user names with the exception of admin are deleted. The
password for the user admin is set to the default (āadminā).
Set CMOS Backup Default All connection blade configuration backups and all server blade BIOS
backups are deleted.