EasyManua.ls Logo

Fujitsu PRIMERGY TX200 S5

Fujitsu PRIMERGY TX200 S5
110 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TX200 S5 Options Guide 43
Processors Replacing the heat sin
k
6.3 Replacing the heat sink
Ê Open the server and remove system fan 2 (or 2&4) as described in the
chapter “Preparation”.
Ê Press the heat sink retaining clips downward and inward to release them.
Ê Swing the heat sink retaining clips up as far as they will go.
Ê Loosen the heat sink by turning it back and forth and then lift it out.
Ê Clean the upper side of the processor using a lint-free cloth.
Ê Remove the protective cover from the new heat sink.
Ê Mount the heat sink on the processor so that the side with the visible copper
heat pipes is pointing in the direction of the memory slots.
Ê Fold down the two heat sink retaining clips at the same time and lock the
heat sink by returning the heat sink retaining clips to their original position.
Ê Reinstall system fan 2 (or 2&4) as described in the chapter “Completion”.
Ê Close the server, connect it to the power outlet, and switch it on as described
in the chapter “Completion”.

Other manuals for Fujitsu PRIMERGY TX200 S5

Related product manuals