Loading...
replacefru(8)
System Administration 125
NAME replacefru - replace a field replaceable unit (FRU)
SYNOPSIS replacefru
replacefru -h
DESCRIPTION The replacefru(8) command replaces an FRU. The command allows the user to
select, confirm, and replace the FRU interactively using menus.
The following FRUs can be replaced using the replacefru(8) command.
CPU/Memory Board unit (CMU)
I/O unit (IOU)
FAN unit (FANU)
Power supply unit (PSU)
XSCF unit (XSCFU)
DC-DC converter (DDC_A)
Privileges You must have fieldeng privileges to run this command.
Refer to setprivileges(8) for more information.
OPTIONS The following option is supported.
EXIT STATUS The following exit values are returned:
SEE ALSO addboard(8), addfru(8), deleteboard(8), deletefru(8), setupfru(8),
showdcl(8), showdomainstatus(8), showfru(8), showhardconf(8), testsb(8),
unlockmaintenance(8)
-h Displays usage statement.
0 Successful completion.
>0 An error occurred.