viewaudit(8)
526 SPARC Enterprise Mx000 Servers XSCF Reference Manual • Last Revised September 2008
-B date-time Selects records that occurred before date-time. The date-time
argument is in local time. the -A and -B options can be
used together to form a range. Valid values for date-time are
either absolute or offset:
Absolute date-time : yyyymmdd[hh[mm[ss]]]
where:
yyyy = year (1970 is the earliest valid value)
mm = month (0112)
dd = day (0131)
hh = hour (0023)
mm = minutes (0059)
ss = seconds (0059)
Offset date-time: +n d|h|m|s
where:
n = number of units
d = days
h = hours
m = minutes
s = seconds
Offset is only available with the -B option and must be
used with -A.
(The default value is 00 for hh, mm and ss.)
-C Appends the number of records that matched the selection
criteria to the end of the output.