2. WIRING
2-3
2.1 Panel Computer Unit PCU-3000
2.1.1 Connections to the PCU-3000
Referring to the figure below, connect the PCU to its respective peripherals.
Depending on your power supply (applied voltage), choose the correct cabling for
power input, referring to the table below.
Voltage Cable Description
230 VAC FS-CABLE EU cable Type F “Schuko”, included with PCU-3000.
100 VAC 80099 cable Type B, included with PCU-3000.
24 VDC JIS cable See paragraph 2.1.3 to fabricate the power
cable.
24 VDC
*3
DPYC-1.5
100-230 VAC
*3
Unused
Unused
SSD port
(port1 not used)
To external monitor
DVI-D/D S-LINK5M cable
DVI-D
To VDR
DVIP(I)-DP cable
Note: VDR devices must be
connected via a frame synchronizer
DVI-I
To HUB-100, Sensor Adapter or VDR
FR-FTPC-CY cable
LAN2
To HUB-3000
DTI-C5E350 VCV cable
LAN1
USB1 to 4
*1
AIS, GPS, GYRO, LOG
*2
Serial Interface ports
To ship’s earth
Ground cable, IV-2sq.
*3
: AC and DC input cannot
be used simultaneously
USB1
USB2
USB3
USB4
: 5139U Black (keyboard)
: DVD drive (with ext. cable)
: RCU-030
: USB storage
*1
C1 port
C2 port
C3 port
C4 port
TTYCS-4/TTYCSLA-4 or
TTYCS-1Q/TTYCSLA-1Q
TTYCS-1Q or
TTYCSLA-1Q
*2
Grounding point for serial ports
(Used when flushmounting only)
USB1
USB2
USB3
USB4
C1
C2
C3
C4
IEC61162-1/2
IEC
EUR TYPE F
US TYPE B
IEC