EasyManua.ls Logo

Furuno FMD3100 - Fabricating JIS Cables; Fabrication of TTYCS Series; Fabrication of TTYCSLA Series

Furuno FMD3100
81 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2. WIRING
2-7
2.1.5 Fabricating JIS cables
Fabricate JIS cables as shown below to connect them to the WAGO connectors on
the PCU-3000 (See following page for WAGO connection).
After fabricating the cable, attach the WAGO connector and EMI ferrite core (sup-
plied). For how to attach the WAGO connecor and EMI ferrite core, see the next page.
Shield
6
5
100
*
30
Armor
Sheath
200
Fabrication of TTYCS series
Vinyl tape (Width: 20)
After exposing cores, wind shield
around the armor.
Clamp here with cable clamp.
Fabrication of TTYCSLA series
Pass a heat shrink tube (local supply) onto the
drain wire, then attach the crimp-on lug (supplied
with the PCU-3000) to it.
Sheath
Armor
Vinyl tape (Width: 20)
Clamp here with cable clamp.
Drain wire
Crimp-on lug (supplied)
80
150
6
NOTE: All dimension in millimeters
LAN2 LAN1
USB2
USB1
USB4
USB3
For flush mounted
installations, connect the
drain wire to this terminal.
C1
C2C4
C3
IEC61162-1/2

Table of Contents

Related product manuals