2. WIRING
2-23
How to set alarm output (MC-3030D)
Use the connector J3 to J6 on the MC_OUT Board (24P0117) to select NC (normal
close) or NO (normal open) for alarm output 1 to 8.
Connector J3
Connector J4
Connector J5
Connector J6
Pin
#
Signal
name
In/
Out
Remarks
Alarm1 NO
Out
Alarm1 NC
Out
Alarm2 NO
Out
Alarm2 NC
Out
1A1
Out
Alarm1
Out
MPYC-12 No connection
-
2COM1 MPYC-12
3B1 No
connection
4A2
Alarm2
Out
-
MPYC-12 No connection
5COM2 MPYC-12
6 B2 No connection
Pin
#
Signal
name
In/
Out
Remarks
Alarm3 NO
Out
Alarm3 NC
Out
Alarm4 NO
Out
Alarm4 NC
Out
1A3
Out
Alarm3
Out
MPYC-12 No connection
-
2COM3 MPYC-12
3B3 No
connection
4A4
Alarm4
Out
-
MPYC-12 No connection
5COM4 MPYC-12
6 B4 No connection
Pin
#
Signal
name
In/
Out
Remarks
Alarm5 NO
Out
Alarm5 NC
Out
Alarm6 NO
Out
Alarm6 NC
Out
1A5
Out
Alarm5
Out
MPYC-12 No connection
-
2 COM5 MPYC-12
3B5 No
connection
4A6
Alarm5
Out
-
MPYC-12 No connection
5COM6 MPYC-12
6 B6 No connection
Pin
#
Signal
name
In/
Out
Remarks
Alarm7 NO
Out
Alarm7 NC
Out
Alarm8 NO
Out
Alarm8 NC
Out
1A7
Out
Alarm7
Out
MPYC-12 No connection
-
2COM7 MPYC-12
3B7 No
connection
4A8
Alarm8
Out
-
MPYC-12 No connection
5COM8 MPYC-12
6 B8 No connection