2. WIRING
2-8
2.4 Remote Controllers (option)
The processor unit has two ports for connection of two remote controllers.
The Distributor FAP-6800 enables connection of three NFU (Non Follow-Up) type remote
controllers to the processor unit.
Note 1: Connect remote controllers having connectors to the distributor FAP-6800.
Note 2: After the connection of remote controller, set the remote controller type on the
SYSTEM SETUP menu. (See page 3-15.)
Remote controllers with connector Remote controller without connector
FAP-5551 (dial), FAP-6211 (button),
FAP-6221 (lever), FAP-6231 (dodge)
FAP-5552 (dial), FAP-6212 (button),
FAP-6222 (lever), FAP-6232
2.4.1 Example remote controller connections
No distributor
Any two remote controllers can be connected.
FAP-5552, FAP-6212,
or FAP-6222
Processor unit
FAP-5552, FAP-6212,
or FAP-6222
Connection of remote controllers without distributor
Dial type remote controller
For dial-type remote controller, the distributor cannot be used.
FAP-5552 (dial)
Processor unit
FAP-5552 (dial)
Connection of dial type