GAGGIA ANIMA 02 TECHNICAL SPECIFICATIONS
Pag. 3/5
2.2.2. Speci cation for the measurement of the Milk products temperature.
Milk evaluation
To carry out the test, a partially skimmed UHT milk with a percentage of grease between 1.5-1.8%
at a refrigerator temperature Trefr. (between 4 to 10°C) must be used.
The milk product must be checked on a beaker of 250 ml of capability and with an inner diameter
of 70mm, brewing 100gr of product.
Parameters to be respected:
The parameters to be respected are: milk temperature and height of the cream. Each of these pa-
rameters, however, must be evaluated depending on the type of system used for the production of
hot milk.
Actually three types of devices are present on the appliances:
Manual system (pannarello)
Semi-Automatic system (cappuccinatore)
Automatic system (carafe, Pinless wonder system, etc.)
Milk temperature in the beaker:
System without Pinless Wonder: e.g. Xelsis, Exprelia, Syntia, Intelia.
With milk at Trefr. (about 4-10 °C): 36
System with Pinless Wonder: e.g. New royal, Energica Pure, Intelia EVO Latte.
With milk at Trefr. (about 4-10 °C): 45
Height of the milk cream in the beaker:
Manual system (pannarello) 15mm on 100gr. of brewed product
Semi-automatic system (cappuccinatore) 20mm on 100gr. of brewed product
Automatic system: carafe, cappuccinatore, Pinless wonder e.g. (New Royal, Energica Pure, Intelia
EVO latte) 20mm on 100gr. of brewed product
How to measure the temperature of the milk.
1. The measurement is carried out in the beaker, immediately after the end of milk brew, positioned
on a non-metallic surface, using a thermocouple thermometer (eg. Type K). Stop the preparation
of mixed product: at the end of milk brewing, where “One Touch product” function is present.
2. The temperature is measured by immersing the probe of the thermometer, positioning the probe
inside the beaker at about 10mm from the bottom of the container, then the probe moves in
a circular motion for 3-5 turns, stopping at the end, at the center of the beaker. It detects the
maximum temperature reached in a time of relief between 3 to 5 seconds. It is important the
mixing of milk before the measurement at 10mm from the bottom of the beaker. If the mixing is
correct, temperature, for a few fractions of a second, during the measurement should not oscil-
late.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gaggia Anima and is the answer not in the manual?

Gaggia Anima Specifications

General IconGeneral
Product typeEspresso machine
Capacity in cups- cups
Coffee input typeCoffee beans, Ground coffee
Coffee maker typeFully-auto
Country of originItaly
Appliance placementCountertop
Water tank capacity1.8 L
Coffee beans capacity250 g
Maximum operating pressure15 bar
Number of grinder settings5
Reservoir for brewed coffeeCup
Number of temperature settings3
Adjustable coffee spout height range110 - 150 mm
Control typeButtons
Display typeLCD
Product colorBlack
Housing materialAcrylonitrile butadiene styrene (ABS), Stainless steel
Multi beverage-
Quantity per pack1 pc(s)
AC input voltage230 V
AC input frequency50 Hz
Power consumption (standby)1 W
Weight and Dimensions IconWeight and Dimensions
Depth430 mm
Width221 mm
Height340 mm
Weight7900 g