EasyManuals Logo

Galil Motion Control DMC-40x0 Series User Manual

Default Icon
280 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #165 background imageLoading...
Page #165 background image
DMC-40x0 Command Reference _LR • 155
_LR
FUNCTION: Reverse Limit Switch Operand
DESCRIPTION:
The _LR operand contains the state of the reverse limit switch for the specified axis.
The operand is specified as: _LRn where n is the specified axis.
Note: This operand is affected by the configuration of the limit switches set by the command CN:
For CN -1:
_LRn = 1 when the limit switch input is inactive*
_LRn = 0 when the limit switch input is active*
For CN 1:
_LRn = 0 when the limit switch input is inactive*
_LRn = 1 when the limit switch input is active*
* The term “active” refers to the condition when at least 1 ma of current is flowing through the
input circuitry. The input circuitry can be configured to sink or source current to become
active. See Chapter 3 in the User’s Manual for further details.
EXAMPLES:
MG _LRA Display the status of the A axis reverse limit switch

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Galil Motion Control DMC-40x0 Series and is the answer not in the manual?

Galil Motion Control DMC-40x0 Series Specifications

General IconGeneral
BrandGalil Motion Control
ModelDMC-40x0 Series
CategoryController
LanguageEnglish

Related product manuals