EasyManuals Logo

Galil Motion Control DMC-40x0 Series User Manual

Default Icon
280 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #190 background imageLoading...
Page #190 background image
180 OT DMC-40x0 Command Reference
OT
FUNCTION: Off on encoder failure time
DESCRIPTION:
Sets the time in samples (milliseconds for TM1000) that the controller will wait for motion after
the OV threshold has been exceeded. The controller can detect a failure on either or both
channels of the encoder. This is accomplished by checking on whether motion of at least 4
counts is detected whenever the torque exceeds a preset level (OV) for a specified time (OT).
Note that for this function to work properly it is necessary to have a non-zero value for KI.
ARGUMENTS: OTn,n,n,n,n,n,n,n where
n is the number of samples between 2 and 32000
? returns the last value set
USAGE: DEFAULTS:
While Moving Yes Default Value 30
In a Program Yes Default Format 5.0
Command Line Yes
Controller Usage
ALL CONTROLLERS
OPERAND USAGE:
_OTn contains the OT value for the specified axis.
RELATED COMMANDS:
OA Off on encoder failure
OV Off on encoder failure voltage
EXAMPLES:
OTX=10 Set time to 10 milliseconds (TM1000)
OVX=5 Set voltage to 5
OAX=1 Enable encoder detection feature

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Galil Motion Control DMC-40x0 Series and is the answer not in the manual?

Galil Motion Control DMC-40x0 Series Specifications

General IconGeneral
BrandGalil Motion Control
ModelDMC-40x0 Series
CategoryController
LanguageEnglish

Related product manuals