DMC-40x0 Command Reference UL • 247
UL
FUNCTION: Upload
DESCRIPTION:
The UL command transfers data from the controller to a host computer. Programs are sent
without line numbers. The Uploaded program will be followed by a <control>Z as an end of
text marker.
ARGUMENTS: None
USAGE: DEFAULTS:
While Moving Yes Default Value 0
In a Program No Default Format -
Command Line Yes
Controller Usage
ALL CONTROLLERS
OPERAND USAGE:
When used as an operand, _UL gives the number of available variables. The number of available
variables is 510.
RELATED COMMAND:
DL Download
EXAMPLES:
UL; Begin upload
#A Line 0
NO This is an Example Line 1
NO Program Line 2
EN Line 3
<cntrl>Z Terminator